Devices that sync to Microsoft Entra ID (formerly Azure AD) from on-premises Active Directory but do not complete registration with the Microsoft Entra device registration service show a status of Pending. Pending devices cannot complete single sign-on or receive device-based Conditional Access policies.

A common cause is a device moving to an organizational unit outside the Microsoft Entra Connect sync scope and then moving back. When this occurs, the device may not complete registration and can remain in a pending status. For more information, see Pending devices in Microsoft Entra ID in the Microsoft Entra documentation.

  1. On the affected device, open Command Prompt as an administrator.
  2. Run dsregcmd /leave to unregister the device.
  3. Run dsregcmd /status to verify that the device is unregistered.
  4. Restart the device.
  5. After the device restarts, run dsregcmd /status again and verify that AzureAdjoined displays YES.
  6. Log in to the Microsoft Entra admin center and verify that a registration timestamp appears for the device.
The device registration process restarts, and the user can register the device.